Record a pattern in LIVE RECORDING mode
1 / 3
- ComboHold [RECORD] and press [PLAY] to enter LIVE RECORDING (double-press [PLAY] to toggle auto-quantize). The sequencer starts and [RECORD] flashes red.
- PressTap the [TRIG] keys in real time (TRIG_1 shown). Turning DATA ENTRY knobs records parameter locks.
- PressPress [PLAY] to exit LIVE RECORDING while the sequencer keeps playing.
Result: Trigs (and any parameter locks) are recorded in real time.
Source: manual §9.3
Related: Record a pattern in GRID RECORDING mode · Record in STEP RECORDING mode