Elektron

← All procedures

Record trigs in STEP RECORDING mode (STANDARD)

MAIN_VOLUMEMain VolumeLEVEL_DATA — Preset PoolLevel/DataSCREENDigitakt IIENC_AAENC_BBENC_CCENC_DDENC_EEENC_FFENC_GGENC_HHTRIG_PARAMS — QuantizeTRIGQuantizeSRC — MachineSRCMachineFLTR — SetupFLTRSetupAMP — SequencerAMPSequencerFX — Send FXFXSend FXMOD — MixerMODMixerPRESET_KIT — PerformPerformSETTINGS — Save ProjSave ProjSAMPLING — SamplesSamplesTEMPO — Tap TempoTap TempoRECORD — CopyCopyPLAY — ClearClearSTOP — PastePasteFUNCFUNCKEYBOARD — KB SetupKB SetupTRK — Mute ModeTRKMute ModePTN — BankPTNBankSONG — Song EditSONGSong EditYES — SaveYESSaveNO — ReloadNOReloadUP — Trig Mode^Trig ModeLEFT — uTime-<uTime-DOWN — Trig ModevTrig ModeRIGHT — uTime+>uTime+PAGE — Fill/SetupPAGEFill/SetupTRIG_11TRIG_22TRIG_33TRIG_44TRIG_55TRIG_66TRIG_77TRIG_88TRIG_99TRIG_1010TRIG_1111TRIG_1212TRIG_1313TRIG_1414TRIG_1515TRIG_1616
1 / 7
  1. ComboHold [RECORD] and press [STOP] to enter STEP RECORDING mode. The [RECORD] key double-blinks red. (Press [STOP] twice while keeping [RECORD] pressed to toggle between STANDARD and JUMP mode.)
  2. PressPress a [TRIG] key to select the active step where you want to start adding note trigs (TRIG_1 shown). The active step double-blinks green. You can also use [LEFT]/[RIGHT] to select the active step or skip steps.
  3. ComboHold [FUNC] and press a [TRIG 1-16] key (TRIG_1 shown) to add a note trig on the corresponding track to the active step. The active step automatically advances.
  4. NoteTo add note trigs chromatically: select a track with [TRK] + [TRIG 1-16], press [KEYBOARD] to toggle the chromatic keyboard on, then hold [KEYBOARD] and press any lit [TRIG] key to add a note trig with that note value. Use [UP]/[DOWN] to transpose in octaves.
  5. PressTo remove a trig or add a rest, position the active step on it and press [NO]. The active step automatically advances.
  6. NoteTo add a parameter lock, press and hold a [TRIG] key and turn the DATA ENTRY knob that controls the parameter you want to lock.
  7. PressPress [RECORD] to exit STEP RECORDING mode.

Result: Note trigs are placed step by step on the sequencer.

Source: manual §10.2

Related: Compose a pattern in GRID RECORDING mode · Record trigs in LIVE RECORDING mode · Activate STEP RECORDING